Metaforsa 3/3.plus

From Larnitech wiki page
Revision as of 14:37, 8 April 2024 by Support (talk | contribs) (Created page with "*τοποθετήστε τον αισθητήρα και τους ενεργοποιητές (αν δεν είναι προεγκατεστημένοι), ρυθμίστε το...")
Jump to navigation Jump to search
Other languages:
Deutsch • ‎English • ‎Nederlands • ‎bosanski • ‎dansk • ‎español • ‎français • ‎italiano • ‎lietuvių • ‎magyar • ‎polski • ‎português • ‎română • ‎slovenčina • ‎slovenščina • ‎čeština • ‎русский • ‎српски / srpski • ‎українська • ‎Ἀρχαία ἑλληνικὴ
MF3/MF3.plus
METAFORSA 3 MF3-14.png
Output ports
Number of switched channels10
Number of dimming channels4
Peak load16 A
Max load per dimming channel0.5 A (110 W at 220 V)
Dimmer typeMOSFET
Input ports
Number of discrete inputs28
General
Max CAN devices4 (can be extended with the license) 99 (for Metaforsa 3.plus)
Max CAN bus length800 m (twisted pair CAT5e)
Max current per CAN bus500 mA
Other
Supply voltage11.5...27.5 V DC
Dimentions9U, 156x90x58 mm


Εισαγωγή

Το εγχειρίδιο εγκατάστασης METAFORSA SMART HOUSE περιγράφει τη διαδικασία εγκατάστασης, συναρμολόγησης, λειτουργίας και ρύθμισής του. Κατά την εργασία με το σύστημα, πρέπει να συμμορφώνεστε αυστηρά με όλες τις απαιτήσεις που ορίζονται σε αυτό το εγχειρίδιο. Η μη συμμόρφωση μπορεί να οδηγήσει σε ζημιά στη συσκευή, αστοχία της, ηλεκτροπληξία, πυρκαγιά και άλλες επιπτώσεις. Ο κατασκευαστής διατηρεί το δικαίωμα να κάνει αλλαγές σε αυτό το εγχειρίδιο χωρίς προηγούμενη ειδοποίηση. Αυτό το εγχειρίδιο αποτελεί αναπόσπαστο μέρος του συστήματος και θα παραμείνει στον πελάτη τελικής χρήσης.

Χαρακτηριστικά

  • Υποστήριξη 10 καθολικών εξόδων:
    • Φώτα
    • Βαλβίδες θέρμανσης NC/NO
    • Περσίδες
    • Πύλες 1 ή 2 πόλων
    • 1 ή 2πολικές βαλβίδες
    • Κλειδαριές NC/NO
    • Μονάδες fan coil
  • 4 εξόδους μείωσης της φωτεινότητας
  • 28 είσοδοι που υποστηρίζουν:
    • Κουμπιά
    • Κουμπιά LED
    • Διακόπτες
    • Διακόπτες καλαμιών
    • Αισθητήρες διαρροής
    • Ανιχνευτές κίνησης
    • Αισθητήρες θερμοκρασίας
    • Λωρίδες LED
    • Λωρίδες RGB 3-4-5 καναλιών
    • Λωρίδες WS2812B
    • Συσκευές RS485 (μόνο για Metaforsa 3.plus)
  • Θύρα επέκτασης
  • Ρελέ με επαφές AgSnO2 με ονομαστική τιμή ρεύματος εισόδου 80A 20ms
  • Σύνδεση cloud και έλεγχος όλων των συστημάτων του σπιτιού
  • Φωνητικός έλεγχος (Siri, Alexa, Google Home)

Απαιτήσεις ασφαλείας

ΠΡΟΣΟΧΗ! Όλες οι εργασίες που σχετίζονται με την εγκατάσταση, τη σύνδεση, την εγκατάσταση, το σέρβις και την υποστήριξη πρέπει να εκτελούνται από εξειδικευμένο προσωπικό με επαρκείς δεξιότητες και εμπειρία στην εργασία με ηλεκτρικό εξοπλισμό.

Για να αποφευχθεί ο κίνδυνος πυρκαγιάς, ηλεκτροπληξίας, ζημιάς στο σύστημα ή/και τραυματισμού, η εγκατάσταση και η συναρμολόγηση του συστήματος πρέπει να εκτελούνται σύμφωνα με τις οδηγίες που αναφέρονται παρακάτω:


  • Όλες οι εργασίες σύνδεσης πρέπει να εκτελούνται χωρίς ρεύμα.
  • χρησιμοποιήστε κατάλληλα εργαλεία και προσωπική προστασία από ηλεκτροπληξία.
  • μην χρησιμοποιείτε κατεστραμμένα καλώδια, καλώδια και συνδέσμους.
  • αποφύγετε την αναδίπλωση των καλωδίων και των καλωδίων.
  • μην τσιμπήσετε ή τσακίσετε τα καλώδια και τα καλώδια ασκώντας υπερβολική δύναμη. Διαφορετικά, οι εσωτερικοί αγωγοί του καλωδίου και των καλωδίων μπορεί να απογυμνωθούν ή να σπάσουν.
  • Μην χρησιμοποιείτε την πρίζα με κακές επαφές για σύνδεση.
  • μην υπερβαίνετε το όριο των παραμέτρων φορτίου που καθορίζεται σε αυτό το εγχειρίδιο.
  • το τμήμα σύρματος των αγωγών τροφοδοσίας υπόκειται στις προδιαγραφές για όριο πυκνότητας ρεύματος, τύπο μόνωσης και υλικό σύρματος. Το ελαφρύ τμήμα μπορεί να προκαλέσει υπερθέρμανση του καλωδίου και πυρκαγιά.


Όταν εργάζεστε με το σύστημα μετά την παροχή τάσης ΠΟΤΕ:

  • πραγματοποιήστε σύνδεση/αποσύνδεση των βυσμάτων.
  • ανοιχτές μονάδες και αισθητήρες.

Διαμόρφωση συστήματος και σκοπός

Σκοπός του συστήματος

Το METAFORSA SMART HOUSE είναι μια έτοιμη λύση για την αυτοματοποίηση οικιστικών και επαγγελματικών χώρων, ξενοδοχειακών συγκροτημάτων που περιλαμβάνει τα πιο επιθυμητά χαρακτηριστικά του Smart House.


Η συσκευή διαθέτει 10 κανάλια ελέγχου, 4 κανάλια dimming και 28 κανάλια εισόδου ποσ.


Οι καθολικές έξοδοι μπορούν να χρησιμοποιηθούν για τον έλεγχο: Οι καθολικές είσοδοι σάς επιτρέπουν να συνδέσετε:
Φωτισμός Κουμπιά/κουμπιά LED/μονάδες μεταγωγής
Υποδοχές Διακόπτες μαγνητικού καλαμιού
Ενδοδαπέδια θέρμανση Αισθητήρες διαρροής
Κουρτίνα Ανιχνευτές κίνησης
Ενεργοποιητές πύλης Αισθητήρες θερμοκρασίας
Ύδρευση Λωρίδες LED/λωρίδες RGB 3-4-5 καναλιών/Λωρίδες WS2812B
Βαλβίδες θέρμανσης Συσκευές RS485*

* – Μόνο για το Metaforsa 3.plus


'Θύρα επέκτασης


Η θύρα επέκτασης σάς επιτρέπει να αναβαθμίσετε το σύστημα συνδέοντας βοηθητικό εξοπλισμό, όπως η ηλεκτρονική μονάδα ελέγχου για φωτισμό LED, ρύθμιση φωτεινότητας, συσκευές μέτρησης και άλλα στοιχεία. Το πακέτο, το οποίο είναι πλήρως έτοιμο για εγκατάσταση, περιλαμβάνει το βασικό υλικό και λογισμικό.

Περιεχόμενα πακέτου

Το πακέτο συνοδεύεται στάνταρ με:

Mainframe METAFORSA 3/3.plus 1 τεμ
Τροφοδοτικό MEANWELL DR-15-12 1 τεμ
Αισθητήρας κίνησης CW-MSD 3 τεμ
Αισθητήρας διαρροής FW-WL.B 2 τεμ
Στοιχείο ευαίσθητο στη θερμοκρασία FW-TS 4 τεμ
Μαγνητικός διακόπτης καλαμιού (αισθητήρας θέσης παραθύρου/πόρτας) 4 τεμ
Φίλτρο θορύβου καλωδίου Ethernet 1 τεμ
Καλώδιο τροφοδοσίας 1 τεμ

Βασικές τεχνικές προδιαγραφές του Συστήματος

Οι βασικές προδιαγραφές και τα χαρακτηριστικά της ενότητας METAFORSA 3/3.plus φαίνονται στον πίνακα 1

Τραπέζι 1
Προδιαγραφές Εννοια
'Θύρες εξόδου
Αριθμός εναλλασσόμενων καναλιών 10
Αριθμός αλλαγμένων ομάδων 10
Αριθμός καναλιών μείωσης φωτεινότητας 4
Τάση μεταγωγής 0-250 V AC/DC
Φορτίο αιχμής (ένα κανάλι) 16Α
Φορτίο αιχμής (συσκευή) 160Α
Μέγιστο φορτίο ανά κανάλι μείωσης φωτεινότητας 0,5A (110W στα 220V)
Τύπος ροοστάτη MOSFET
Τύπος φορτίου Dimmer R,C
Τύπος φωτισμού χείλος εκφυγής
Τύπος σύνδεσης καλωδίου τροφοδοσίας σύνδεσμος
Επιτρεπόμενο τμήμα του καλωδίου τροφοδοσίας για σύνδεση στην πρίζα:
καλώδιο ενός αγωγού
καλώδιο πολλαπλών αγωγών
καλώδιο πολλαπλών αγωγών με μύτη

0,5 … 4mm2
0,5 … 4mm2
0,5 … 2,5 mm2
Θύρες εισόδου
Αριθμός διακριτών εισόδων 28
Μέγιστη ονομαστική τιμή ρεύματος στους συνδετήρες τάσης συνεχούς ρεύματος 5 mA*
Άλλα'
Θερμοκρασία περιβάλλοντος λειτουργίας 0 … +45°С
Θερμοκρασία αποθήκευσης/μεταφοράς -10 … +50°С
Επιτρεπτή υγρασία 0 … 95% (χωρίς συμπύκνωση)
Τροφοδοσία 11,5 … 27,5 V DC
24V, 0,75A Συνιστάται
Μέγιστη ζήτηση 0,5Α
Διαθέσιμες διεπαφές Ethernet, CAN
Τύπος λεωφορείου CAN (4-σύρματα)
CAN (4-wire) 800 m** (συνεστραμμένο ζεύγος CAT5e)
Τύπος σύρματος CAN FTP Cat 5E
Τύπος σύνδεσης CAN Συνδετήρας
Μέγιστο μήκος ψηφιακής γραμμής 30 μ
Τύπος καλωδίου ψηφιακής γραμμής UTP/FTP Cat 5E
Μέγιστο μήκος LAN 100 μ
Τύπος καλωδίου LAN UTP/FTP Cat 5E
Τύπος σύνδεσης LAN Σύνδεσμος RJ-45
Ποσότητα θυρών RS485 1***
Ταχύτητα μεταφοράς δεδομένων 1200-115200 b/s***
Προδιαγραφές διαστάσεων 9U, 156x90x58 mm
Υλικό κελύφους ABS
Κάσα IP40
Τύπος εγκατάστασης εξοπλισμού DIN-rail (EN 60715)
Βάρος 400 γρ

* – Τα κανάλια εξόδου πρέπει να συνδέονται μόνο με χρήση ενισχυτή που χρησιμοποιεί σήμα 5V PWM από την έξοδο IO ως είσοδο

** – η εγκατάσταση πρόσθετων μονάδων τροφοδοσίας απαιτείται για μεγάλες γραμμές. το μέγιστο μήκος της γραμμής μπορεί να μειωθεί από διάφορους παράγοντες παρεμβολής

*** – Μόνο για το Metaforsa 3.plus

Γενική δομή του Συστήματος

Η γενική όψη της μονάδας εμφανίζεται στο 'εικ. 1


Fig. 1 Γενική άποψη ενότητας


1 — σύνδεσμος για εφαρμογή φορτίου
2 — σύνδεσμος για εφαρμογή λαμπτήρων φωτισμού
3 — βύσμα τροφοδοσίας
4 — Υποδοχή δικτύου Ethernet
5-6 — υποδοχές για γενικά κανάλια εισόδου/εξόδου
7 — σύνδεσμος για μονάδα επέκτασης.


Επισκόπηση των εξωτερικών βυσμάτων της συσκευής METAFORSA: Στο επάνω μέρος του περιβλήματος ('εικ. 1') υπάρχει:


  • υποδοχή (1) — Σύνδεση συσκευών.
  • Βύσμα (2) — Σύνδεση λαμπτήρων μείωσης της έντασης του φωτός.


Στο κάτω μέρος του περιβλήματος ('εικ. 1') υπάρχει:


  • βύσμα (3) — σύνδεση τροφοδοτικού μονάδας.
  • σύνδεση (4) — Σύνδεση δικτύου Ethernet.
  • υποδοχές (5-6) — σύνδεση καναλιών γενικής εισόδου/εξόδου – κουμπιά, διακόπτες καλαμιού, κουμπιά LED, αισθητήρες διαρροής, αισθητήρες κίνησης, αισθητήρες θερμοκρασίας, λωρίδες LED, ταινίες RGB 3-4-5 καναλιών, ταινίες WS2812B, συσκευές RS485 ( Μόνο για το Metaforsa 3.plus);
  • υποδοχή (7) — σύνδεση μονάδας επέκτασης.

Η φυσική διαμόρφωση και η αντιστοίχιση σημείων επαφής κάθε βύσματος φαίνονται στον πίνακας 2.

Τραπέζι 2
Σύνδεσμος Επικοινωνία Ανάθεση
Out.png 1-10 Εφαρμογή φορτίου (λαμπτήρες φωτός, θερμικοί ενεργοποιητές κ.λπ.)
Dimm.png D1-4, L, N Εφαρμογή φόρτωσης (λαμπτήρες φωτισμού)
Ενδείξεις κατάστασης συσκευής Οι δείκτες κατάστασης της μονάδας περιγράφονται στον πίνακα 3
24vconn.png +24V
GND
+24V — τροφοδοσία μονάδας από εξωτερικό τροφοδοτικό 24 V GND — κοινό
Rj45.jpg RJ45 Υποδοχή για σύνδεση LAN
IOC CONN.png In1-14, In15-28 GND Σύνδεση συσκευών ελέγχου (κουμπιά, κουμπιά LED, διακόπτες μαγνητικού καλαμιού, ανιχνευτές κίνησης, αισθητήρες διαρροής, αισθητήρες θερμοκρασίας κ.λπ.):
In1 … In28 — λογικές είσοδοι
GND — κοινές
Can.jpg VCC
GND
L
H
Σύνδεση εξωτερικών μονάδων για CAN-bus
VСС — Έξοδος 24V για εξωτερικές συσκευές τροφοδοτικό
GND — συνηθισμένο
L — Δίαυλος δεδομένων CAN-L
H — Δίαυλος δεδομένων CAN-H
Table3
Indicator Status Description
Power G.png Power
E.png Power not available
Activity Y.png Data communication
E.png Data communication not available
Error E.png No errors
R.png Communication error
R.pngR.png Module overheat
R.pngR.pngR.png Dimmer outputs module overload
R.pngR.pngR.pngR.png Absence of power on dimmers, if in configuration

Εγκατάσταση και συναρμολόγηση συστήματος

Πριν συνδέσετε το σύστημα, πρέπει:


  • τοποθετήστε τον αισθητήρα και τους ενεργοποιητές (αν δεν είναι προεγκατεστημένοι), ρυθμίστε τους αισθητήρες και τους ενεργοποιητές.
  • τοποθετήστε τη μονάδα και το τροφοδοτικό.


Note: The module must be installed near the power supply voltage source.


CAUTION! AC power voltage must be provided to the system input through the circuit breaker assembly. It should be installed close to the power supply.
  1. The power of circuit breaker assembly must comply with the load capacity;
  2. Nothing else than the phase conductors can be connected to the module, the neutral wire is connected separately.


Typical diagram of METAFORSA 3/3.plus module connection is shown in fig. 3.

Fig. 3


Connection of the actuators

Connection of the lights/electric contactor/heating thermal actuator

lamp
Fig. 4
Such actuators as light, electric contactor, heating thermal actuator should be switched on any of the outputs 1 – 10, the neutral wire and the ground wire should be connected directly to the switchboard. The example of connection is shown in Fig.4.


Connection of high load device

Contactor Recomended contactors:
  • ABB ESB series
  • Schneider Acti 9 iCT series
  • Hager ESC series.


Connection of single-pole water/gas supply valve

Caution: Before applying power to the load, make sure that the output configuration of METAFORSA module is correct. The incorrect configuration or incorrect connection can cause the module failure and/or failure of the equipment connected to it, and even a fire.
valve
Fig. 5
The single pole water/gas supply valve is connected to any of the outputs of 1 – 10, the (neutral wire and the ground wire are connected directly to the switchboard. The example of connection is shown in Fig.5.


Connection of double-pole water/gas supply valve

Caution: Before applying power to the valve, it is necessary to ensure the output configuration of METAFORSA module is correct. The incorrect configuration can cause the voltage application simultaneously to both channels of the valve, which may result in the module failure and/or failure of the equipment connected to it, and even a fire.
valve
Fig. 6
Two adjacent contact points (for example, 3, 4) are used to connect the double-pole water/gas supply valve; in these conditions the neutral wire and the ground wire are connected directly to the switchboard. The example of connection is shown in Fig.6.


Connection of single-pole gate actuator

Caution: Before applying power to the module, you should properly configure access to the application. The contacts incorrectly configured can result in the module failure and/or failure of the equipment connected to it, and even a fire.

1pgate
Fig. 7
Any contact point (for example, 3) is used to connect the single-pole gate drive controllers. The example of connection is shown in Fig.7.


Connection of double-pole gate actuator

Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.

2pgate
Fig. 8
Two adjacent contact points (for example, 3, 4) should be used to connect the double-pole gate drive controller. The example of connection is shown in Fig.8.


Connection of curtain/jalousie/shutter actuator with 220V force control

Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.

Pjalousie
Fig. 9
Two adjacent contact points (for example, 3, 4) should be used to connect the curtain/jalousie/rolladens actuator, in these conditions the neutral wire and the ground wire are connected directly to the switchboard. The example of connection is shown in Fig.9.


Connection of curtain/jalousie/shutter actuator with low-voltage control

Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire.

ljalousie
Fig. 10
Two adjacent contact points (for example, 3, 4) should be used to connect the curtain/jalousie/rolladens actuator with low-voltage control. The example of connection is shown in Fig.10.

Connection of sensing elements/switches/buttons

Connection of motion sensors/leakage sensors

The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +5V and GND of the relevant group. The example of connection is shown in Fig.11.

IOC CONN LM.png
Fig. 11 connection of motion sensors/leakage sensors


Connection of buttons/switches/magnetic reed switches

Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in Fig. 12-13.

Buttons MF3.png

Fig. 12 connection of buttons/switching units
Reed-sv MF3.png

Fig. 13 connection of the magnetic reed switches (window/door position sensors)

Connection of temperature sensors

Temperature sensors are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in Fig. 14.

IOC CONN T.png

Fig. 14 connection of temperature sensors

RGB connection scheme

CAUTION! Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input

IOC RGB EX.png

Fig. 15 RGB connection

WS2812B connection scheme

IOC CONN WS.png

Fig. 16 WS2812B connection

RS485 connection scheme

CAUTION! RS485 connection is only available for Metaforsa 3.plus and only occurs on 21 channel

MF3plus rs485.png

Fig. 17 RS485 connection

Connection of auxiliary equipment.

Expansion modules include Larnitech equipment connected through the CAN-bus. Such equipment includes: dimmers, RGB-backlit control modules, multimode sensors, etc. The equipment connected to the expansion port is defined automatically and does not require any preset tuning. Connector contact pin assignment is defined in Table 4. The example of connection is shown in Fig. 18.

CAN MF3.png
Caution! The 120 ohm terminating resistors should be installed at the end connectors between L and H contact points of CAN-bus. Ensure the connection is correct. The incorrect connection may cause sensor and/or module malfunction.

Module installation and connection procedure

ATTENTION! You must precisely follow the recommendations listed in the Security Requirements section hereof.
  1. Install the module in the switchboard on the DIN-rail and fix it with the special latch on the module base.
  2. Fasten the supply unit on the left side of the module.
  3. Connect the connector (4) having the noise filter pre-installed which is supplied complete with the module.
  4. Connect the connectors (5), (6).
  5. Connect the connectors (1), (2).
  6. Connect the connector (3).
  7. Apply power to the supply unit of METAFORSA module.
  8. Wait until the module is loaded, then configure it in accordance with the System Setup Instructions.
  9. Apply power to the connectors (1), (2).
  10. Check all equipment for proper operation.

METAFORSA module shut-off and deinstallation procedure

  1. De-energize the module by disconnecting the circuit breaker assembly of the load power supply and METAFORSA module supply unit. Verify the voltage is absent on the terminals (1), (2) of the connector wires and on the input terminals of the supply unit.
  2. Disconnect the load power supply connectors (1), (2).
  3. Disconnect the connector (3).
  4. Disconnect the connectors (4)-(6).
  5. Remove the module from the DIN-rail, releasing the latch at the bottom of the module base.

Hardware setup

To configure and control METAFORSA SMART HOUSE, you must install Larnitech software on your smartphone or tablet, which is available in App Store and Play Market. After installation, follow the System Setup Instructions.

Fault diagnostics and handling

The following are some possible faults and ways of fault handling. If you have any difficulty, or face the fault undeclared here, please contact the Technical Support: [1] or [support@larnitech.com]. There are also some tips in the FAQ section at our website [2].

The actuators do not operate:

  • ensure the outputs are properly configured in the application (see System Setup Instructions);
  • check the connection is correct in accordance with table 2 and paragraph 3.6;
  • ensure the power is supplied to the input power contact , i.e. all circuit breaker assembly are ON.
  • verify the operability of the connected equipment.

The module is off, indication absent:

  • check the connection to 24V supply unit as shown in table 2 (contacts pin assignment);
  • check the connection of the supply unit to 220V power mains, the indicator should be ON.

Network connection fault:

  • ensure the Ethernet cable is properly wired and connected to the connector;
  • ensure the LED status indicators are ON on the Ethernet connector;
  • check the LAN configuration is correct, Ethernet cable loops are absent;
  • METAFORSA module and the device you are connecting from are in the same network.

hold integer 0-10000 1-10 by default hold is the same as runtime hold is the bridging time in miliseconds, is used for gate and jalousie, lock; Example: hold=3500


The sensors do not operate:

  • ensure the inputs are properly configured in the application (System Setup Instructions);
  • check the connection is correct in accordance with table 2 and paragraph 3.7;
  • ensure the METAFORSA module is ON: circuit breaker assembly is closed, indication on the supply unit is ON, the module indication corresponds to the operating status – table 3;
  • check the power supply availability on the sensors;
  • check the integrity of lines laid to the sensors.

The auxiliary equipment does not operate:

  • check the connection is correct in accordance with table 2 and paragraph 3.8-9;
  • ensure the METAFORSA module is ON: circuit breaker assembly is closed, indication on the supply unit is ON, the module indication corresponds to the operating status – table 3;
  • check the integrity of the CAN lines, voltage supply on the modules.

HW Settings

Name Type, range SUBID Default Description
runtime integer 0-100 1-10 15 runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole);


Example: runtime=15

runtimeopen integer 0-60000 Blinds subId Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000
runtimeclose integer 0-60000 Blinds subId Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000
hold integer 0-10000 1-10 500 hold is the bridging time in milliseconds, is used for gate and jalousie (by default hold is the same as runtime for jalousie and gate), lock; Example: hold=3500
def string 'ON' 1-10 'OFF' def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
stop Char ‘R’ 1-7 (for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’
out char[10] 98 'LLLLHHHHP-' Each char is responsible for the type of a particular channel
  • 'L'-Lamp;
  • 'M'-Lamp Inverse;
  • 'J'-Heating NO, valve-heating, normally open;
  • 'H'-Heating NC, valve-heating, normally closed;
  • 'B'-Blinds (2 pole), jalousie/curtains;
  • 'C'-Blinds Inverse (2 pole), jalousie/curtains, invert open-close;
  • 'G'-Gate (2 pole), 2 pole gate;
  • 'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close;
  • 'X'-Gate (1 pole /short press), 1 pole gate;
  • 'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close;
  • 'V'-Valve (2 pole), 2 pole valve;
  • 'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close;
  • 'R'-Valve (1 pole), 1 pole valve,;
  • 'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close;
  • 'K'-Lock (short press);
  • 'N'-Lock (short press) Inverse;
  • 'P'-Blinds (2 pole);
  • 'O'-Blinds Inverse (2 pole), invert open-close;
  • 'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
  • 'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
  • 'Q'-FanCoil. Group3 (Lamp Toggle). For fancoil speed control;
  • 'U'-FanCoil. Group4 (Lamp Toggle). For fancoil speed control;
  • 'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control;
  • '-'-none, nothing is connected.

Example: out='LLB-G-V-W-'

dm char[4] 98 ‘LLLL’ Each char is responsible for the type of a particular channel
  • ‘g’ – use like halogen dimer-lamp
  • ‘s’ – Soft Switch, lamp, when on/off power is supplied/deenergised smoothly (500msec)
  • ‘k’ – Switch, lamp, when on/off power is supplied/deenergised immediately
  • ‘l’ – LED Function, dimmable LED lamps
  • ‘v’ – linear Function of dimming
  • ‘-‘ – Channel disabled
  • ‘+’ – Regular channel

Example: dm=’skl-‘

def integer 0-250 11-14 100 The default brightness level in case of a power reset (1..250). Example: def=250
min integer 0-100 11-14 0 Minimum dimming level, example: min=10
max integer 0-100 11-14 100 Maximum dimming level, example max=95
start integer 0-100 11-14 0 The Start function is used for lamps that lack the minimal voltage to get turned on. If the set value is lower than the start value, the lamp is turned on at the start value and them the light is dimmed down to the set level. Example: start=60
force integer 0-100 11-14 10 Time duration of the starting value (measured in milliseconds). Example: force=20
runtime integer 0-60000 11-14 1000 Runtime is the speed of changing the brightness from ‘min’ to ‘max’ (measured in milliseconds). Example: runtime=1000
offset integer (+/- 0…39) 39-46 '0' sensor values offset; For example, offset is -3.8 :

Example: hw="offset='-3.8'"

io char[28] 98 io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' Each char is responsible for the type of a particular channel
  • '0' - led-dimmer
  • '1' - halogen-dimmer
  • '2' - linear-dimmer
  • '3'..'6' - RGB-3..6 channels
  • 'z' - WS2812B -string
  • 'e' - led-button inverse
  • 'd' - led-button
  • 'c' - button inverse
  • 'b' - button
  • 's' - switch
  • 'k' - contact inverse
  • 'h' - contact
  • 'l' - leak
  • 'n' - Neptun
  • 'v' - motion inverse
  • 'm' - motion
  • 'r' - thermo-resistor
  • 't' - DALLAS
  • '-' - none

Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'

hw string 98 - hw="...", where
  • pwm_invert – PWM inverting [1, 0];
  • lbn_bright – brightness of led buttons, range (0 - 255);
  • f – by default PWM frequency is 1000, range (1 - 5000).

Example:

1hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
Only for Metaforsa 3.plus
cfg string 98 9600/8N1 cfg='SPEED/BPS', where
  • SPEED – baud rate [1200..115200];
  • B – data length [7,8];
  • P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
  • S – stop bit length [1, 1.5 or 2].

Example:

1hw="cfg='9600/8N1'"
[Protocol] string 98 Protocol setting is described by protocol parameter. The following

protocols are supported:

  • 'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
  • 'dmx', DMX protocol;
  • 'CO2' for connecting Larnitech CO2 sensors;
  • 'salda' for connecting Salda ventilation.

Example:

1hw="cfg='9600/8N1' modbus"
echo on; off 98 'off' For settings check out and testing echo parameter can be used. Module

echo-reply can be turned on or off with the help of this parameter.Echo parameter value:

  • 'off'
  • 'on'

Example:

1hw="cfg='9600/8N1' echo='off'"
 1		<item addr="349:1" auto-period="600" cfgid="197" name="Lamp 1" type="lamp"/>
 2		<item addr="349:2" auto-period="600" cfgid="197" name="Lamp 2" type="lamp"/>
 3		<item addr="349:3" auto-period="600" cfgid="197" name="Lamp 3" type="lamp"/>
 4		<item addr="349:4" auto-period="600" cfgid="197" name="Lamp 4" type="lamp"/>
 5		<item addr="349:5" auto-period="600" cfgid="197" name="Lamp 5" type="lamp"/>
 6		<item addr="349:6" cfgid="197" name="Radiator" temperature-lag="0.2" type="valve-heating">
 7			<automation name="Eco" temperature-level="16"/>
 8			<automation name="Comfort" temperature-level="22"/>
 9			<automation name="Hot" temperature-level="25"/>
10		</item>
11		<item addr="349:7" cfgid="197" name="Radiator" temperature-lag="0.2" type="valve-heating">
12			<automation name="Eco" temperature-level="16"/>
13			<automation name="Comfort" temperature-level="22"/>
14			<automation name="Hot" temperature-level="25"/>
15		</item>
16		<item addr="349:8" cfgid="197" name="Radiator" temperature-lag="0.2" type="valve-heating">
17			<automation name="Eco" temperature-level="16"/>
18			<automation name="Comfort" temperature-level="22"/>
19			<automation name="Hot" temperature-level="25"/>
20		</item>
21		<item addr="349:9" cfgid="197" name="Jalousie" sub-type="120" type="jalousie"/>
22		<item addr="349:11" auto-period="600" cfgid="197" name="Dimmer 1" type="dimmer-lamp"/>
23		<item addr="349:12" auto-period="600" cfgid="197" name="Dimmer 2" type="dimmer-lamp"/>
24		<item addr="349:13" auto-period="600" cfgid="197" name="Dimmer 3" type="dimmer-lamp"/>
25		<item addr="349:14" auto-period="600" cfgid="197" name="Dimmer 4" type="dimmer-lamp"/>
26		<item addr="349:16" cfgid="197" name="Door 1" type="door-sensor"/>
27		<item addr="349:17" cfgid="197" name="Door 2" type="door-sensor"/>
28		<item addr="349:18" cfgid="197" name="Door 3" type="door-sensor"/>
29		<item addr="349:19" cfgid="197" name="Door 4" type="door-sensor"/>
30		<item addr="349:20" cfgid="197" name="Door 5" type="door-sensor"/>
31		<item addr="349:21" cfgid="197" name="Door 6" type="door-sensor"/>
32		<item addr="349:22" cfgid="197" name="Door 7" type="door-sensor"/>
33		<item addr="349:23" cfgid="197" name="Door 8" type="door-sensor"/>
34		<item addr="349:24" cfgid="197" name="Door 9" type="door-sensor"/>
35		<item addr="349:25" cfgid="197" name="Door 10" type="door-sensor"/>
36		<item addr="349:26" cfgid="197" name="Door 11" type="door-sensor"/>
37		<item addr="349:27" cfgid="197" name="Door 12" type="door-sensor"/>
38		<item addr="349:28" cfgid="197" name="Door 13" type="door-sensor"/>
39		<item addr="349:29" cfgid="197" name="Door 14" type="door-sensor"/>
40		<item addr="349:30" cfgid="197" name="Door 15" type="door-sensor"/>
41		<item addr="349:31" cfgid="197" name="Door 16" type="door-sensor"/>
42		<item addr="349:32" cfgid="197" name="Door 17" type="door-sensor"/>
43		<item addr="349:33" cfgid="197" name="Door 18" type="door-sensor"/>
44		<item addr="349:34" cfgid="197" name="Door 19" type="door-sensor"/>
45		<item addr="349:35" cfgid="197" name="Door 20" type="door-sensor"/>
46		<item addr="349:36" cfgid="197" name="Door 21" type="door-sensor"/>
47		<item addr="349:37" cfgid="197" name="Door 22" type="door-sensor"/>
48		<item addr="349:38" cfgid="197" name="Door 23" type="door-sensor"/>
49		<item addr="349:39" cfgid="197" name="Door 24" type="door-sensor"/>
50		<item addr="349:40" cfgid="197" name="Door 24" type="door-sensor"/>
51		<item addr="349:41" cfgid="197" name="Door 25" type="door-sensor"/>
52		<item addr="349:43" cfgid="197" name="IR receiver" type="ir-receiver"/>
53		<item addr="349:44" cfgid="197" name="RS485" type="com-port"/>
54		<item addr="349:90" cfgid="197" name="Current" system="yes" type="current-sensor"/>
55		<item addr="349:95" cfgid="197" name="Temperature" system="yes" type="temperature-sensor"/>
56		<item addr="349:96" cfgid="197" name="Temperature" system="yes" type="temperature-sensor"/>
57		<item addr="349:97" cfgid="197" name="Temperature" system="yes" type="temperature-sensor"/>
58		<item addr="349:98" cfgid="197" hw="out='LLLLLHHHB-' dm='LLLL' io='KKKKKKKKKKKKKKKKKKKKUKKKKKK-'" logic-ver="19" name="Temperature" sn="2533726919" system="yes" type="temperature-sensor"/>
59		<item addr="349:100" cfgid="197" name="RS232" type="com-port"/>