Output ports
Number of switched channels10
Number of dimming channels4
Peak load16 A
Max load per dimming channel0.5 A (110 W at 220 V)
Dimmer typeMOSFET
Input ports
Number of discrete inputs28
General
Max CAN devices4 (can be extended with the license) 99 (for Metaforsa 3.plus)
Max CAN bus length800 m (twisted pair CAT5e)
Max current per CAN bus500 mA
Other
Supply voltage11.5...27.5 V DC
Dimentions9U, 156x90x58 mm


Introductie

METAFORSA SMART HOUSE Installatiehandleiding beschrijft de procedure voor de installatie, montage, bediening en instelling. Tijdens het werken met het systeem dient u zich strikt te houden aan alle eisen die in deze handleiding worden gesteld. Het niet naleven ervan kan leiden tot schade aan het apparaat, defecten ervan, elektrische schokken, brand en andere gevolgen. De fabrikant behoudt zich het recht voor om zonder voorafgaande kennisgeving wijzigingen in deze handleiding aan te brengen. Deze handleiding is een integraal onderdeel van het systeem en blijft bij de eindgebruiker.

Features

  • 10 universele uitgangen ondersteunen:
    • Lichten
    • NC/NO verwarmingskleppen
  • Jaloezieën
    • 1 of 2-polige poorten
    • 1 of 2-polige kleppen
    • NC/NO sloten
    • Ventilatorconvectoren
  • 4 dimuitgangen
  • 28 ingangen die ondersteunen:
    • Knoppen
    • LED knoppen
    • Schakelaars
    • Schakelaars
    • Leksensoren
    • Bewegingsmelders
    • Temperatuursensoren
    • LED-strips
    • 3-4-5-kanaals RGB-strips
    • WS2812B-strips
    • RS485-apparaten (alleen voor Metaforsa 3.plus)
  • Uitbreidingspoort
  • Relais met AgSnO2-contacten geschikt voor 80 A 20 ms inschakelstroom
  • Cloud-verbinding en besturing van alle huissystemen
  • Spraakbesturing (Siri, Alexa, Google Home)

Vertaald met DeepL.com (gratis versie)

Veiligheidseisen

VOORZICHTIGHEID! Alle werkzaamheden met betrekking tot de installatie, aansluiting, opstelling, service en ondersteuning moeten worden uitgevoerd door gekwalificeerd personeel met voldoende vaardigheden en ervaring in het werken met elektrische apparatuur.

Om het risico op brand, elektrische schokken, schade aan het systeem en/of persoonlijk letsel te voorkomen, moet de installatie en montage van het systeem worden uitgevoerd in overeenstemming met de onderstaande instructies:


  • alle aansluitwerkzaamheden moeten zonder stroom worden uitgevoerd;
  • gebruik geschikt gereedschap en persoonlijke bescherming tegen elektrische schokken;
  • gebruik geen beschadigde kabels, draden en connectoren;
  • voorkom het vouwen van kabels en draden;
  • knel of knik de kabels en draden niet door te veel kracht uit te oefenen. Anders kunnen de binnenste geleiders van de kabels en draden worden gestript of gebroken;
  • Gebruik geen stopcontact met slechte contacten om aan te sluiten;
  • overschrijd de limiet van de belastingsparameters zoals aangegeven in deze handleiding niet;
  • het draadgedeelte van de voedingsgeleiders is onderhevig aan de specificaties voor stroomdichtheidslimiet, isolatietype en draadmateriaal. Lichte sectie kan leiden tot oververhitting van de kabel en brand.


Bij werkzaamheden met het systeem na spanningstoevoer NOOIT:

  • aansluiten/loskoppelen van connectoren;
  • open modules en sensoren.

Systeemconfiguratie en doel

Doel van het systeem

METAFORSA SMART HOUSE is een kant-en-klare oplossing voor de automatisering van residentiële en commerciële gebouwen en hotelcomplexen die de meest gewenste kenmerken van Smart House omvat.


Het apparaat heeft 10 bedieningskanalen, 4 dimkanalen en 28 invoerkanalen qty.


Universele uitgangen kunnen worden gebruikt om: Op universele ingangen kun je aansluiten:
Verlichting Knoppen/LED-knoppen/schakeleenheden
Contactdoosconnectoren Magnetische reed-schakelaars
Vloerverwarming Lekdetectors
Bewegingsmelders
Poortbedieningen Temperatuursensoren
LED-strips/3-4-5-kanaals RGB-strips/WS2812B strips
Verwarmingskleppen RS485-apparaten*

* - Alleen voor Metaforsa 3.plus


Uitbreidingspoort


Met de uitbreidingspoort kunt u het systeem upgraden door hulpapparatuur aan te sluiten, zoals de besturingsmodule voor LED-verlichting, dimmen, meetapparatuur en andere elementen. Het pakket, dat volledig installatieklaar is, omvat de basishardware en -software.

Inhoud pakket

Het pakket wordt standaard geleverd met:

1 pc
1 pc
3 stuks
2 stuks
Temperatuurgevoelig element FW-TS 4 stuks
4 st.
1 st.
1 pc

Technische basisspecificaties van het systeem

De basisspecificaties en kenmerken van de module METAFORSA 3/3.plus zijn weergegeven in tabel 1

Tabel 1
Specificatie Betekenis
Uitgangspoorten
Aantal geschakelde kanalen 10
Aantal geschakelde groepen 10
Aantal dimkanalen 4
Commutatiespanning 0-250 V AC/DC
Piekbelasting (één kanaal) 16A
Piekbelasting (apparaat) 160A
Max. belasting per dimkanaal 0,5A (110W bij 220V)
Dimmertype MOSFET
Type dimmerbelasting R,C
Dimtype achterrand
Type aansluiting voedingskabel aansluiting
Toegestane doorsnede van de voedingskabel voor aansluiting op stopcontact:
enkeladerige kabel
meeraderige kabel
meeraderige kabel met punt

0,5 … 4 mm2
0,5 … 4 mm2
0,5 … 2,5 mm2
Invoerpoorten
Aantal discrete ingangen 28
Maximale stroomsterkte op de gelijkstroomspanningsconnectoren 5 mA*
Anders
Bedrijfstemperatuur 0 … +45°С
Opslag-/transporttemperatuur -10 … +50°С
Toegestane vochtigheid 0 … 95% (niet-condenserend)
Voeding 11,5 … 27,5 V DC
24 V, 0,75 A Aanbevolen
Maximale vraag 0,5А
Beschikbare interfaces Ethernet, KAN
Bustype CAN (4-draads)
KAN (4-draads) 800 m** (twisted pair CAT5e)
CAN-draadtype FTP-Cat 5E
CAN-verbindingstype Connector
Maximale lengte digitale lijn 30 m
Digitaal lijnbedradingstype UTP/FTP Cat 5E
LAN maximale lengte 100 m
LAN-draadtype UTP/FTP Cat 5E
LAN-verbindingstype Connector RJ-45
RS485-poorten aantal 1***
Gegevensoverdrachtsnelheid 1200-115200 b/s***
Dimensionale specificaties 9U, 156x90x58 mm
Schelpmateriaal buikspieren
Behuizing IP40
Installatietype apparatuur DIN-rail (EN 60715)
Gewicht 400 gr

* – Uitgangskanalen mogen alleen worden aangesloten met behulp van een versterker die een 5V PWM-signaal van de IO-uitgang als ingang gebruikt

** - voor lange lijnen is het installeren van extra voedingseenheden vereist; de maximale lengte van de lijn kan worden beperkt door verschillende storingsfactoren

*** - Alleen voor Metaforsa 3.plus

Algemene structuur van het systeem

Het algemene overzicht van de module wordt getoond in fig. 1


 


1 - connector voor belastingstoepassing
| - connector voor toepassing met dimlampen
3 - Voedingsconnector
4 - Ethernet netwerk connector
- connector voor uitbreidingsmodule.


Overzicht van de externe connectoren van het METAFORSA-apparaat: Bovenaan de behuizing (fig. 1) bevindt zich:


  • connector (1) — Apparatenaansluiting;
  • connector (2) — Aansluiting lampen dimmen;


Onderaan de behuizing (fig. 1) bevindt zich:


  • connector (3) - voedingsaansluiting voor module;
  • connector (4) - aansluiting ethernetnetwerk;
  • connectoren (5-6) - aansluiting universele in-/uitgangskanalen - knoppen, reed-schakelaars, LED-knoppen, leksensoren, bewegingssensoren, temperatuursensoren, LED-strips, 3-4-5-kanaals RGB-strips, WS2812B-strips, RS485-apparaten (alleen voor Metaforsa 3.plus);
  • connector (7) - aansluiting voor uitbreidingsmodule.

De fysieke configuratie en contactpunttoewijzing van elke connector worden weergegeven in tabel 2.

Tabel 2
Connector Contact Assignment
  1-10 Belastingstoepassing (lampen, thermische aandrijvingen, enz.)
  D1-4, L, N Belastingstoepassing (lampen dimmen)
Apparaatstatusindicatoren De modulestatusindicatoren worden beschreven in tabel 3'.
  +24V
GND
+24V - voeding van de module door een externe 24V-voeding GND - gemeenschappelijk
  RJ45 Aansluiting voor LAN-aansluiting
  In1-14, In15-28 GND Aansluiting regelapparaten (knoppen, LED-knoppen, magnetische reed-schakelaars, bewegingsdetectoren, leksensoren, temperatuursensoren enz:)
In1 ... In28 - logische ingangen
GND - gemeenschappelijk
  VCC
GND
L
H
Aansluiting externe modules voor CAN-bus
С - 24V uitgang voor voeding externe apparaten
GND - common
L - CAN-L databus
H - CAN-H databus
Table3
Indicator Status Description
Power   Power
  Power not available
Activity   Data communication
  Data communication not available
Error   No errors
  Communication error
   Module overheat
    Dimmer outputs module overload
     Absence of power on dimmers, if in configuration

Systeeminstallatie en montage

Voordat u het systeem aansluit, moet u:


  • plaats de sensor en actuatoren (indien niet vooraf geïnstalleerd), stel de sensoren en actuatoren in;
  • plaats de module en de voeding.


Opmerking: De module moet in de buurt van de voedingsspanningsbron worden geïnstalleerd.


VOORZICHTIGHEID! Er moet AC-voedingsspanning worden geleverd aan de systeemingang via de stroomonderbreker. Het moet dichtbij de stroomvoorziening worden geïnstalleerd.
  1. Het vermogen van de stroomonderbreker moet overeenkomen met het draagvermogen;
  2. Niets anders dan de fasegeleiders kunnen op de module worden aangesloten, de nuldraad wordt apart aangesloten.


Een typisch schema van de aansluiting van de METAFORSA 3/3.plus module wordt getoond in fig. 3.

 


Aansluiting van de aandrijvingen

Aansluiting van de verlichting/elektrische schakelaar/thermische actuator voor verwarming

 
Fig. 4
Dergelijke actuatoren zoals licht, elektrische schakelaars en thermische thermische actuatoren moeten worden ingeschakeld op een van de uitgangen 1 – 10, de neutrale draad en de aardedraad moeten rechtstreeks op het schakelbord worden aangesloten. Het aansluitvoorbeeld wordt getoond in Fig. 4.


Aansluiting van apparaat met hoge belasting

  Aanbevolen schakelaars:
  • ABB ESB-serie
  • Schneider Acti 9 iCT-serie
  • Hager ESC-serie.


Aansluiting van eenpolige water-/gastoevoerklep

Let op: Controleer voordat u de belasting inschakelt of de uitgangsconfiguratie van de METAFORSA-module juist is. Een onjuiste configuratie of onjuiste aansluiting kan leiden tot storing van de module en/of storing van de apparatuur die erop is aangesloten, en zelfs tot brand."'
 
Fig. 5
De enkelpolige water-/gasvoorzieningsklep wordt aangesloten op een van de uitgangen 1 - 10, de (neutrale) draad en de aardedraad worden rechtstreeks aangesloten op het schakelbord. Het aansluitvoorbeeld wordt getoond in Fig.5.


Aansluiting van dubbelpolige water-/gastoevoerklep

Let op: Voordat er spanning op de klep wordt gezet, moet gecontroleerd worden of de uitgangsconfiguratie van de METAFORSA-module juist is. Een onjuiste configuratie kan ertoe leiden dat de spanning gelijktijdig op beide kanalen van de klep wordt toegepast, wat kan leiden tot defecten aan de module en/of defecten aan de apparatuur die erop is aangesloten, en zelfs tot brand.
 
Fig. 6
Twee aangrenzende contactpunten (bijvoorbeeld 3, 4) worden gebruikt om de dubbelpolige water-/gas toevoerklep aan te sluiten; in deze omstandigheden worden de neutrale draad en de aardedraad rechtstreeks op het schakelbord aangesloten. Het aansluitvoorbeeld wordt getoond in Fig.6.


Aansluiting van eenpolige poortactor

Let op: Voordat u de module van stroom voorziet, moet u de toegang tot de applicatie correct configureren. Verkeerd geconfigureerde contacten kunnen resulteren in het falen van de module en/of het falen van de daarop aangesloten apparatuur, en zelfs in brand.

 
Fig. 7
Elk contactpunt (bijvoorbeeld 3) wordt gebruikt om de enkelpolige poortaandrijfcontrollers aan te sluiten. Het aansluitvoorbeeld wordt getoond in Fig.7.


Aansluiting van dubbelpolige poortactor

Let op: Voordat u de module van stroom voorziet, moet u de uitgangen in de applicatie correct configureren. Verkeerd geconfigureerde contacten kunnen leiden tot gelijktijdige stroomtoevoer naar beide kanalen, met als gevolg het falen van de module en/of het uitvallen van de daarop aangesloten apparatuur, en zelfs brand.

 
Fig. 8
Er moeten twee aangrenzende contactpunten (bijvoorbeeld 3, 4) worden gebruikt om de dubbelpolige poortaandrijfcontroller aan te sluiten. Het aansluitvoorbeeld wordt getoond in Fig.8.


Aansluiting gordijn-/jaloezie-/rolluikactor met 220V krachtsturing

Let op: Voordat u de module van stroom voorziet, moet u de uitgangen in de applicatie correct configureren. Verkeerd geconfigureerde contacten kunnen leiden tot gelijktijdige stroomtoevoer naar beide kanalen, met als gevolg het falen van de module en/of het uitvallen van de daarop aangesloten apparatuur, en zelfs brand.

 
Fig. 9
Er moeten twee aangrenzende contactpunten (bijvoorbeeld 3, 4) worden gebruikt om de gordijn-/jaloezie-/rolladenactuator aan te sluiten. In deze omstandigheden zijn de neutrale draad en de aardedraad rechtstreeks op het schakelbord aangesloten. Het aansluitvoorbeeld wordt getoond in Fig.9.


Aansluiting gordijn-/jaloezie-/rolluikactor met laagspanningsbesturing

Let op: Voordat u de module van stroom voorziet, moet u de uitgangen in de applicatie correct configureren. Verkeerd geconfigureerde contacten kunnen leiden tot gelijktijdige stroomtoevoer naar beide kanalen, met als gevolg het falen van de module en/of het uitvallen van de daarop aangesloten apparatuur, en zelfs brand.

 
Fig. 10
Er moeten twee aangrenzende contactpunten (bijvoorbeeld 3, 4) worden gebruikt om de gordijn-/jaloezie-/rolladenactuator met laagspanningsregeling aan te sluiten. Het aansluitvoorbeeld wordt getoond in Fig.10.

Aansluiting van sensorelementen/schakelaars/knoppen

Aansluiting bewegingssensoren/leksensoren

De bewegingssensoren dienen aangesloten te worden op een willekeurige vrije ingang in1-in28; in deze omstandigheden wordt hun stroom aangesloten op de contactpunten van +5V en GND van de betreffende groep. Het aansluitvoorbeeld wordt getoond in Fig. 11.

 
Fig. 11 aansluiting van bewegingssensoren/leksensoren


Connection of buttons/switches/magnetic reed switches

Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in Fig. 12-13.

 

Fig. 12 connection of buttons/switching units
 

Fig. 13 connection of the magnetic reed switches (window/door position sensors)

Connection of temperature sensors

Temperature sensors are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in Fig. 14.

 

Fig. 14 connection of temperature sensors

RGB connection scheme

CAUTION! Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input

 

Fig. 15 RGB connection

WS2812B connection scheme

 

Fig. 16 WS2812B connection

RS485 connection scheme

CAUTION! RS485 connection is only available for Metaforsa 3.plus and only occurs on 21 channel

 

Fig. 17 RS485 connection

Connection of auxiliary equipment.

Expansion modules include Larnitech equipment connected through the CAN-bus. Such equipment includes: dimmers, RGB-backlit control modules, multimode sensors, etc. The equipment connected to the expansion port is defined automatically and does not require any preset tuning. Connector contact pin assignment is defined in Table 4. The example of connection is shown in Fig. 18.

 
Caution! The 120 ohm terminating resistors should be installed at the end connectors between L and H contact points of CAN-bus. Ensure the connection is correct. The incorrect connection may cause sensor and/or module malfunction.

Module installation and connection procedure

ATTENTION! You must precisely follow the recommendations listed in the Security Requirements section hereof.
  1. Install the module in the switchboard on the DIN-rail and fix it with the special latch on the module base.
  2. Fasten the supply unit on the left side of the module.
  3. Connect the connector (4) having the noise filter pre-installed which is supplied complete with the module.
  4. Connect the connectors (5), (6).
  5. Connect the connectors (1), (2).
  6. Connect the connector (3).
  7. Apply power to the supply unit of METAFORSA module.
  8. Wait until the module is loaded, then configure it in accordance with the System Setup Instructions.
  9. Apply power to the connectors (1), (2).
  10. Check all equipment for proper operation.

METAFORSA module shut-off and deinstallation procedure

  1. De-energize the module by disconnecting the circuit breaker assembly of the load power supply and METAFORSA module supply unit. Verify the voltage is absent on the terminals (1), (2) of the connector wires and on the input terminals of the supply unit.
  2. Disconnect the load power supply connectors (1), (2).
  3. Disconnect the connector (3).
  4. Disconnect the connectors (4)-(6).
  5. Remove the module from the DIN-rail, releasing the latch at the bottom of the module base.

Hardware setup

To configure and control METAFORSA SMART HOUSE, you must install Larnitech software on your smartphone or tablet, which is available in App Store and Play Market. After installation, follow the System Setup Instructions.

Fault diagnostics and handling

The following are some possible faults and ways of fault handling. If you have any difficulty, or face the fault undeclared here, please contact the Technical Support: [1] or [support@larnitech.com]. There are also some tips in the FAQ section at our website [2].

The actuators do not operate:

  • ensure the outputs are properly configured in the application (see System Setup Instructions);
  • check the connection is correct in accordance with table 2 and paragraph 3.6;
  • ensure the power is supplied to the input power contact , i.e. all circuit breaker assembly are ON.
  • verify the operability of the connected equipment.

The module is off, indication absent:

  • check the connection to 24V supply unit as shown in table 2 (contacts pin assignment);
  • check the connection of the supply unit to 220V power mains, the indicator should be ON.

Network connection fault:

  • ensure the Ethernet cable is properly wired and connected to the connector;
  • ensure the LED status indicators are ON on the Ethernet connector;
  • check the LAN configuration is correct, Ethernet cable loops are absent;
  • METAFORSA module and the device you are connecting from are in the same network.

hold integer 0-10000 1-10 by default hold is the same as runtime hold is the bridging time in miliseconds, is used for gate and jalousie, lock; Example: hold=3500


The sensors do not operate:

  • ensure the inputs are properly configured in the application (System Setup Instructions);
  • check the connection is correct in accordance with table 2 and paragraph 3.7;
  • ensure the METAFORSA module is ON: circuit breaker assembly is closed, indication on the supply unit is ON, the module indication corresponds to the operating status – table 3;
  • check the power supply availability on the sensors;
  • check the integrity of lines laid to the sensors.

The auxiliary equipment does not operate:

  • check the connection is correct in accordance with table 2 and paragraph 3.8-9;
  • ensure the METAFORSA module is ON: circuit breaker assembly is closed, indication on the supply unit is ON, the module indication corresponds to the operating status – table 3;
  • check the integrity of the CAN lines, voltage supply on the modules.

HW Settings

Name Type, range SUBID Default Description
runtime integer 0-100 1-10 15 runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole);


Example: runtime=15

runtimeopen integer 0-60000 Blinds subId Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000
runtimeclose integer 0-60000 Blinds subId Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000
hold integer 0-10000 1-10 500 hold is the bridging time in milliseconds, is used for gate and jalousie (by default hold is the same as runtime for jalousie and gate), lock; Example: hold=3500
def string 'ON' 1-10 'OFF' def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
stop Char ‘R’ 1-7 (for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’
out char[10] 98 'LLLLHHHHP-' Each char is responsible for the type of a particular channel
  • 'L'-Lamp;
  • 'M'-Lamp Inverse;
  • 'J'-Heating NO, valve-heating, normally open;
  • 'H'-Heating NC, valve-heating, normally closed;
  • 'B'-Blinds (2 pole), jalousie/curtains;
  • 'C'-Blinds Inverse (2 pole), jalousie/curtains, invert open-close;
  • 'G'-Gate (2 pole), 2 pole gate;
  • 'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close;
  • 'X'-Gate (1 pole /short press), 1 pole gate;
  • 'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close;
  • 'V'-Valve (2 pole), 2 pole valve;
  • 'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close;
  • 'R'-Valve (1 pole), 1 pole valve,;
  • 'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close;
  • 'K'-Lock (short press);
  • 'N'-Lock (short press) Inverse;
  • 'P'-Blinds (2 pole);
  • 'O'-Blinds Inverse (2 pole), invert open-close;
  • 'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
  • 'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
  • 'Q'-FanCoil. Group3 (Lamp Toggle). For fancoil speed control;
  • 'U'-FanCoil. Group4 (Lamp Toggle). For fancoil speed control;
  • 'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control;
  • '-'-none, nothing is connected.

Example: out='LLB-G-V-W-'

dm char[4] 98 ‘LLLL’ Each char is responsible for the type of a particular channel
  • ‘g’ – use like halogen dimer-lamp
  • ‘s’ – Soft Switch, lamp, when on/off power is supplied/deenergised smoothly (500msec)
  • ‘k’ – Switch, lamp, when on/off power is supplied/deenergised immediately
  • ‘l’ – LED Function, dimmable LED lamps
  • ‘v’ – linear Function of dimming
  • ‘-‘ – Channel disabled
  • ‘+’ – Regular channel

Example: dm=’skl-‘

def integer 0-250 11-14 100 The default brightness level in case of a power reset (1..250). Example: def=250
min integer 0-100 11-14 0 Minimum dimming level, example: min=10
max integer 0-100 11-14 100 Maximum dimming level, example max=95
start integer 0-100 11-14 0 The Start function is used for lamps that lack the minimal voltage to get turned on. If the set value is lower than the start value, the lamp is turned on at the start value and them the light is dimmed down to the set level. Example: start=60
force integer 0-100 11-14 10 Time duration of the starting value (measured in milliseconds). Example: force=20
runtime integer 0-60000 11-14 1000 Runtime is the speed of changing the brightness from ‘min’ to ‘max’ (measured in milliseconds). Example: runtime=1000
offset integer (+/- 0…39) 39-46 '0' sensor values offset; For example, offset is -3.8 :

Example: hw="offset='-3.8'"

io char[28] 98 io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' Each char is responsible for the type of a particular channel
  • '0' - led-dimmer
  • '1' - halogen-dimmer
  • '2' - linear-dimmer
  • '3'..'6' - RGB-3..6 channels
  • 'z' - WS2812B -string
  • 'e' - led-button inverse
  • 'd' - led-button
  • 'c' - button inverse
  • 'b' - button
  • 's' - switch
  • 'k' - contact inverse
  • 'h' - contact
  • 'l' - leak
  • 'n' - Neptun
  • 'v' - motion inverse
  • 'm' - motion
  • 'r' - thermo-resistor
  • 't' - DALLAS
  • '-' - none

Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'

hw string 98 - hw="...", where
  • pwm_invert – PWM inverting [1, 0];
  • lbn_bright – brightness of led buttons, range (0 - 255);
  • f – by default PWM frequency is 1000, range (1 - 5000).

Example:

1hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
Only for Metaforsa 3.plus
cfg string 98 9600/8N1 cfg='SPEED/BPS', where
  • SPEED – baud rate [1200..115200];
  • B – data length [7,8];
  • P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
  • S – stop bit length [1, 1.5 or 2].

Example:

1hw="cfg='9600/8N1'"
[Protocol] string 98 Protocol setting is described by protocol parameter. The following

protocols are supported:

  • 'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
  • 'dmx', DMX protocol;
  • 'CO2' for connecting Larnitech CO2 sensors;
  • 'salda' for connecting Salda ventilation.

Example:

1hw="cfg='9600/8N1' modbus"
echo on; off 98 'off' For settings check out and testing echo parameter can be used. Module

echo-reply can be turned on or off with the help of this parameter.Echo parameter value:

  • 'off'
  • 'on'

Example:

1hw="cfg='9600/8N1' echo='off'"
 1		<item addr="349:1" auto-period="600" cfgid="197" name="Lamp 1" type="lamp"/>
 2		<item addr="349:2" auto-period="600" cfgid="197" name="Lamp 2" type="lamp"/>
 3		<item addr="349:3" auto-period="600" cfgid="197" name="Lamp 3" type="lamp"/>
 4		<item addr="349:4" auto-period="600" cfgid="197" name="Lamp 4" type="lamp"/>
 5		<item addr="349:5" auto-period="600" cfgid="197" name="Lamp 5" type="lamp"/>
 6		<item addr="349:6" cfgid="197" name="Radiator" temperature-lag="0.2" type="valve-heating">
 7			<automation name="Eco" temperature-level="16"/>
 8			<automation name="Comfort" temperature-level="22"/>
 9			<automation name="Hot" temperature-level="25"/>
10		</item>
11		<item addr="349:7" cfgid="197" name="Radiator" temperature-lag="0.2" type="valve-heating">
12			<automation name="Eco" temperature-level="16"/>
13			<automation name="Comfort" temperature-level="22"/>
14			<automation name="Hot" temperature-level="25"/>
15		</item>
16		<item addr="349:8" cfgid="197" name="Radiator" temperature-lag="0.2" type="valve-heating">
17			<automation name="Eco" temperature-level="16"/>
18			<automation name="Comfort" temperature-level="22"/>
19			<automation name="Hot" temperature-level="25"/>
20		</item>
21		<item addr="349:9" cfgid="197" name="Jalousie" sub-type="120" type="jalousie"/>
22		<item addr="349:11" auto-period="600" cfgid="197" name="Dimmer 1" type="dimmer-lamp"/>
23		<item addr="349:12" auto-period="600" cfgid="197" name="Dimmer 2" type="dimmer-lamp"/>
24		<item addr="349:13" auto-period="600" cfgid="197" name="Dimmer 3" type="dimmer-lamp"/>
25		<item addr="349:14" auto-period="600" cfgid="197" name="Dimmer 4" type="dimmer-lamp"/>
26		<item addr="349:16" cfgid="197" name="Door 1" type="door-sensor"/>
27		<item addr="349:17" cfgid="197" name="Door 2" type="door-sensor"/>
28		<item addr="349:18" cfgid="197" name="Door 3" type="door-sensor"/>
29		<item addr="349:19" cfgid="197" name="Door 4" type="door-sensor"/>
30		<item addr="349:20" cfgid="197" name="Door 5" type="door-sensor"/>
31		<item addr="349:21" cfgid="197" name="Door 6" type="door-sensor"/>
32		<item addr="349:22" cfgid="197" name="Door 7" type="door-sensor"/>
33		<item addr="349:23" cfgid="197" name="Door 8" type="door-sensor"/>
34		<item addr="349:24" cfgid="197" name="Door 9" type="door-sensor"/>
35		<item addr="349:25" cfgid="197" name="Door 10" type="door-sensor"/>
36		<item addr="349:26" cfgid="197" name="Door 11" type="door-sensor"/>
37		<item addr="349:27" cfgid="197" name="Door 12" type="door-sensor"/>
38		<item addr="349:28" cfgid="197" name="Door 13" type="door-sensor"/>
39		<item addr="349:29" cfgid="197" name="Door 14" type="door-sensor"/>
40		<item addr="349:30" cfgid="197" name="Door 15" type="door-sensor"/>
41		<item addr="349:31" cfgid="197" name="Door 16" type="door-sensor"/>
42		<item addr="349:32" cfgid="197" name="Door 17" type="door-sensor"/>
43		<item addr="349:33" cfgid="197" name="Door 18" type="door-sensor"/>
44		<item addr="349:34" cfgid="197" name="Door 19" type="door-sensor"/>
45		<item addr="349:35" cfgid="197" name="Door 20" type="door-sensor"/>
46		<item addr="349:36" cfgid="197" name="Door 21" type="door-sensor"/>
47		<item addr="349:37" cfgid="197" name="Door 22" type="door-sensor"/>
48		<item addr="349:38" cfgid="197" name="Door 23" type="door-sensor"/>
49		<item addr="349:39" cfgid="197" name="Door 24" type="door-sensor"/>
50		<item addr="349:40" cfgid="197" name="Door 24" type="door-sensor"/>
51		<item addr="349:41" cfgid="197" name="Door 25" type="door-sensor"/>
52		<item addr="349:43" cfgid="197" name="IR receiver" type="ir-receiver"/>
53		<item addr="349:44" cfgid="197" name="RS485" type="com-port"/>
54		<item addr="349:90" cfgid="197" name="Current" system="yes" type="current-sensor"/>
55		<item addr="349:95" cfgid="197" name="Temperature" system="yes" type="temperature-sensor"/>
56		<item addr="349:96" cfgid="197" name="Temperature" system="yes" type="temperature-sensor"/>
57		<item addr="349:97" cfgid="197" name="Temperature" system="yes" type="temperature-sensor"/>
58		<item addr="349:98" cfgid="197" hw="out='LLLLLHHHB-' dm='LLLL' io='KKKKKKKKKKKKKKKKKKKKUKKKKKK-'" logic-ver="19" name="Temperature" sn="2533726919" system="yes" type="temperature-sensor"/>