Line 5: |
Line 5: |
| | image = LED-DRV_3A.png | | | image = LED-DRV_3A.png |
| | outCount = 4 | | | outCount = 4 |
− | | peakl = 2A | + | | peakl = 3A |
| | voltage = 12/24 V DC | | | voltage = 12/24 V DC |
| | dim = ??x??x?? mm | | | dim = ??x??x?? mm |
Line 13: |
Line 13: |
| | | |
| <!--T:3--> | | <!--T:3--> |
− | This module allows interpreting controlling signal from DW-IO for 12/24V LED/RGB strip. | + | This module allows interpretation of controlling signals from IO connections for 12/24V LED/RGB strips. |
| | | |
| <!--T:4--> | | <!--T:4--> |
Line 35: |
Line 35: |
| | | |
| <!--T:6--> | | <!--T:6--> |
− | [[File:RGBC EXA.png|500px]] | + | [[File:LED-DRV_connection_scheme.png|800px]] |
| | | |
− | ==Example of connection RGB LED with Amp== <!--T:7-->
| + | ==Module parameters== <!--T:7--> |
− | | |
− | <!--T:8-->
| |
− | [[File:RGBC EXA2.png|500px]]
| |
− | | |
− | ==Module parameters== <!--T:9--> | |
| | | |
| <!--T:10--> | | <!--T:10--> |
| {{ Mp | | {{ Mp |
− | | outqty = 3 | + | | outqty = 4 |
| | involtage = 11.5 … 25V | | | involtage = 11.5 … 25V |
| | currtype = DC | | | currtype = DC |
Line 54: |
Line 49: |
| | power = 11.5 … 27.5 V DC from CAN | | | power = 11.5 … 27.5 V DC from CAN |
| | maxcur24v = 25 mA | | | maxcur24v = 25 mA |
− | | bustype = CAN (4-wire)
| |
| | instalation = Free | | | instalation = Free |
| | case = ABS | | | case = ABS |
Line 63: |
Line 57: |
| }} | | }} |
| | | |
− | ==Module installation and connection procedure== <!--T:11--> | + | ==Module installation and connection procedure== <!--T:8--> |
| | | |
− | <!--T:12--> | + | <!--T:9--> |
| #Connect the outputs. | | #Connect the outputs. |
− | #Connect the CAN connector.
| |
| #Configure the module using LT setup. | | #Configure the module using LT setup. |
| #Apply power to the load. | | #Apply power to the load. |
| #Check all equipment for proper operation. | | #Check all equipment for proper operation. |
| | | |
− | ==Module shut-off and deinstallation procedure== <!--T:13--> | + | ==Module shut-off and deinstallation procedure== <!--T:10--> |
| | | |
− | <!--T:14--> | + | <!--T:11--> |
| #Disconnect the power from the load. | | #Disconnect the power from the load. |
− | #Disconnect the CAN connector.
| |
| #Disconnect the outputs. | | #Disconnect the outputs. |
| | | |
− | ==HW settings== <!--T:15--> | + | ==HW settings== <!--T:12--> |
| {|class="wikitable" | | {|class="wikitable" |
| |- | | |- |